Spans Envirotech Logo

Chemical Dosing Calculator

Calculate daily chemical consumption, stock solution requirements, and dosing pump rate for coagulants, disinfectants, and pH adjustment chemicals used in water and wastewater treatment.

Free · 8 Chemicals · Dosing Pump Sizing

Chemical Dosing Parameters

Calculate daily chemical consumption, stock solution requirement, and dosing pump rate.

Purpose: Coagulation / primary treatment
Note: Dose varies with raw water turbidity. Jar test recommended.

Typical: 2050 mg/L

As-prepared solution concentration

How to Use This Calculator

  1. 1Select the chemical you are dosing. Typical dose ranges are shown to guide your input.
  2. 2Enter the flow rate (KLD) of the stream being dosed and the dose in mg/L from your design or jar test.
  3. 3Enter the stock solution strength (%) you will prepare on-site. The calculator returns stock volume and pump rate.

Formulas

Chemical consumption (kg/day) = Flow (KLD) × Dose (mg/L) ÷ 1000

Stock solution (L/day) = Chemical (kg/d) ÷ (Stock% ÷ 100 × density kg/L)

Dosing pump rate (L/hr) = Stock solution (L/day) ÷ 24

Typical Dose Ranges

ChemicalTypical Dose (mg/L)Purpose
Alum20–50Coagulation
PAC10–40Coagulation
Ferric Chloride20–60Coagulation / P removal
Chlorine / NaOCl2–10Disinfection
Lime50–300pH correction / P removal
Caustic Soda50–500pH increase

Note: Always confirm dose by jar test / pilot trial. Optimal dose varies with water quality.

Need Chemical System Design Support?

Spans Envirotech supplies and commissions chemical dosing systems including coagulation, flocculation, disinfection, and pH control for STPs and ETPs across India.

Contact Us