Aeration Tank Design Calculator

Size an activated sludge aeration tank for STP or ETP design. Get tank volume, HRT, oxygen requirements, air flow, and sludge generation for three process variants.

Free · Extended Aeration · Conventional AS · High Rate

Aeration Tank Design Parameters

Select process type and enter wastewater characteristics to size the aeration tank.

CPCB standard for inland water discharge: ≤ 30 mg/L

How to Use This Calculator

  1. 1Enter the flow rate (KLD) and inlet BOD from lab analysis of your wastewater.
  2. 2Set your target effluent BOD — typically ≤30 mg/L for CPCB inland surface water discharge standards.
  3. 3Choose the process type: Extended Aeration is most common for STPs, Conventional for ETPs with good BOD/COD ratios.

Design Formulas

# F/M (Food-to-Microorganism) Ratio Method

BOD load (kg/d) = Flow (KLD) × BOD_in (mg/L) ÷ 1000

Tank volume (m³) = BOD load (kg/d) × 1000 ÷ (F/M × MLSS)

HRT (hrs) = Tank volume ÷ Flow × 24

O₂ required (kg/d) = BOD removed (kg/d) × 1.5

Air flow (m³/hr) = O₂ (kg/d) ÷ (0.252 × 0.25) ÷ 24

[fine bubble SOTE = 25%, O₂ in air = 21%, density = 1.2 kg/m³]

Process Comparison

ParameterExtended AerationConventional AS
F/M Ratio0.04–0.100.15–0.30
HRT (hrs)18–366–12
MLSS (mg/L)3000–50002000–4000
Sludge ProductionLowMedium
Best ForMunicipal STPs, small ETPsIndustrial ETPs