Aeration Tank Design Calculator
Size an activated sludge aeration tank for STP or ETP design. Get tank volume, HRT, oxygen requirements, air flow, and sludge generation for three process variants.
Free · Extended Aeration · Conventional AS · High RateAeration Tank Design Parameters
Select process type and enter wastewater characteristics to size the aeration tank.
CPCB standard for inland water discharge: ≤ 30 mg/L
How to Use This Calculator
- 1Enter the flow rate (KLD) and inlet BOD from lab analysis of your wastewater.
- 2Set your target effluent BOD — typically ≤30 mg/L for CPCB inland surface water discharge standards.
- 3Choose the process type: Extended Aeration is most common for STPs, Conventional for ETPs with good BOD/COD ratios.
Design Formulas
# F/M (Food-to-Microorganism) Ratio Method
BOD load (kg/d) = Flow (KLD) × BOD_in (mg/L) ÷ 1000
Tank volume (m³) = BOD load (kg/d) × 1000 ÷ (F/M × MLSS)
HRT (hrs) = Tank volume ÷ Flow × 24
O₂ required (kg/d) = BOD removed (kg/d) × 1.5
Air flow (m³/hr) = O₂ (kg/d) ÷ (0.252 × 0.25) ÷ 24
[fine bubble SOTE = 25%, O₂ in air = 21%, density = 1.2 kg/m³]
Process Comparison
| Parameter | Extended Aeration | Conventional AS |
|---|---|---|
| F/M Ratio | 0.04–0.10 | 0.15–0.30 |
| HRT (hrs) | 18–36 | 6–12 |
| MLSS (mg/L) | 3000–5000 | 2000–4000 |
| Sludge Production | Low | Medium |
| Best For | Municipal STPs, small ETPs | Industrial ETPs |
Need a Full Activated Sludge Design?
Our engineers design complete STP and ETP systems including aeration, clarification, sludge handling, and instrumentation. EPC and O&M services available across India.
Contact Our Engineers